ShapeRectangle 2ShapeXXnote2clipboardclockcredit@2xGroupShapeShapeShapeGroup 2GroupHeart - FontAwesomeGroupinstagram@2x (1)magnifying47map-markerGroupphoneShapesocial-pinterest-outlineGroupribbon001-test-tubeShapeShapesocial-youtube-outline

Fact Sheet: Home Aeration Units – Multi-Flo

Home  >  Resources  >  Fact Sheets  >  Fact Sheet: Home Aeration Units – Multi-Flo
Resources
Overview
Fact Sheets
Overview
Fact Sheet: Animal Quarantine
Fact Sheet: Backflow & Backflow Devices
Fact Sheet: Bed Bugs
Fact Sheet: Bedbug Guidelines for Travelers and Public Accommodation Facility Guests
Fact Sheet: Blue-Green Algae/Cyanobacteria Harmful Algal Bloom (HABs) Physician Reference
Fact Sheet: Bureau for Children with Medical Handicaps
Fact Sheet: Church Festival Food Safety
Fact Sheet: Cleaning up After Flood & Sewer Backups
Fact Sheet: Cockroaches
Fact Sheet: Collector Line Tips
Fact Sheet: Commercial Waste Handling and Good House Keeping
Fact Sheet: Connecting to Sewers
Fact Sheet: Cottage Food Operation
Fact Sheet: Dangers of Extreme Cold
Fact Sheet: Daycare Control Measures for Prevention of Communicable Diseases
Fact Sheet: Emergency Pet Kit
Fact Sheet: Extreme Heat
Fact Sheet: Farm Markets
Fact Sheet: Farmers’ Markets
Fact Sheet: Fight the Bite – Facts About Zika Virus
Fact Sheet: Financial Aid for Sewer Connections and Septic System Replacement
Fact Sheet: Fish Fry Food Safety
Fact Sheet: Flood Safety
Fact Sheet: Flooding in a Food Service Operation
Fact Sheet: Food Safety During Power Outages
Fact Sheet: Food Safety When Eating Out
Fact Sheet: Frozen Pipes
Fact Sheet: Gastroenteritis and Norovirus
Fact Sheet: Gastroenteritis in a Retirement/Assisted Living Facility
Fact Sheet: Get Rid of Roaches
Fact Sheet: Guide to Mosquito Control & Mosquito-borne Illnesses
Fact Sheet: Guidelines For Environmental Cleaning and Disinfection of Norovirus
Fact Sheet: Guidelines for Handling Bed Bugs in a School
Fact Sheet: Guidelines for Social Workers, Home Health Care Nurses, and In Home Visitors
Fact Sheet: Guidelines for the Control of a Suspected or Confirmed Outbreak of Viral Gastroenteritis in a Nursing Home
Fact Sheet: Hamilton County Public Health Flood Fact Sheet
Fact Sheet: Hand Washing
Fact Sheet: Handling Water from Swimming Pools and Hot Tubs
Fact Sheet: Heat
Fact Sheet: Hepatitis A
Fact Sheet: Home Aeration Units – Cavitette
Fact Sheet: Home Aeration Units – Coate Aer
Fact Sheet: Home Aeration Units – JET
Fact Sheet: Home Aeration Units – Multi-Flo
Fact Sheet: Home Aeration Units – Oldham
Fact Sheet: Home Swimming Pools
Fact Sheet: Homeowner’s Plumbing Permit
Fact Sheet: Household Sewage Treatment System Tips
Fact Sheet: Household Sewage Treatment Systems & Power Outages
Fact Sheet: How Germs Spread
Fact Sheet: How to be Safe Around Animals
Fact Sheet: Itch Mites
Fact Sheet: Keeping Food Safe During an Emergency
Fact Sheet: Leachfields
Fact Sheet: Lead Poisoning
Fact Sheet: Lice
Fact Sheet: Methicillin-Resistant Staphylococcus Sureus (MRSA)
Fact Sheet: Mold and Mildew
Fact Sheet: MRSA in a Prison Setting
Fact Sheet: Norovirus in Schools
Fact Sheet: Ohio EPA Semi-Public Sewage Disposal System Inspection Program
Fact Sheet: Privacy Practices, Our Legal Duty
Fact Sheet: Private Water System Testing
Fact Sheet: Rabies & Bats
Fact Sheet: Rodent Control
Fact Sheet: Scrap Tires
Fact Sheet: Septic System Abandonment and Sanitary Sewer Connection
Fact Sheet: Septic Systems – AdvanTex AX20 Treatment System
Fact Sheet: Septic Systems – Septic Tanks
Fact Sheet: Septic Systems – Subsurface Sandfilters
Fact Sheet: Sewage Treatment System Owners
Fact Sheet: Sewer Back-ups
Fact Sheet: Storm Drain Overflow
Fact Sheet: Stormwater Pollution and Yard Waste
Fact Sheet: Sump Pumps
Fact Sheet: Tattoos and Piercings
Fact Sheet: Vacuum Sealing + Hazard Analysis Critical Control Point (HACCP)
Fact Sheet: Waste Disposal
Fact Sheet: Water Heater Permits and Inspections
Fact Sheet: Well Disinfection
Fact Sheet: When Do I Need a Plumbing Permit?
Fact Sheet: Whooping Cough
FOI Requests
Links
Partner & Public Health Research
Reports

KNOW THE FACTS!

Home Aeration Units – Multi-Flo

Illustration of your Unit

You currently live in an unsewered area of Hamilton County. The waste from your house is treated by a home aeration unit. These units come in many shapes and sizes. They are sometimes referred to as “cavitettes.” Cavitette is the brand name of one aeration unit used in our county. The other brands used are: Coate Aer, Jet, Multi-Flo, Norweco, and Oldham. Although aeration units have different brand names, the principle of operation is basically the same; air injected into sewage provides agitation and oxygen which allows bacteria to reduce organic waste to carbon dioxide and water.

Managing your Unit

Sewage tank pumpers must be registered with the Health District. The principle purpose of tank pumping is to remove sludge. You may want to be present at the time of pumping to insure all sludge and wastewater is removed. Contracted repairs must be performed by registered professionals. To receive a list of registered pumpers and contractors call the Health District at 513/946-7800.

 

Treatment Process

A properly operating home aeration unit will produce a clear, odorless effluent. The following process is used.

 

Primary

(Pre-Treatment/Settling) There is no separate pretreatment chamber in the Multi-Flo system. Aeration, clarification and filtration are completed in one tank.

 

Aeration

Raw sewage from your home flows directly to the aeration chamber. There injected air from the Multi-Flo aerator provides agitation and oxygen to aerobic bacteria, which reduces organic matter in the wastewater.

 

Multi-Flo Aerator

The Multi-Flo aerator is a submersible aerator that sits at the bottom of the tank. The Multi-Flo aeration unit runs continuously 24 hours a day. The aerator is 1/6 HP 1550 RPM motor with thermal overload protection 120 Volt AC 60Hz, 2.6 amps. The Mulit-Flo aerator is built with a thermal overload switch. If the motor gets too warm, the thermal switch will turn the motor off before permanent damage occurs.

 

Clarification/Filtration

During clarification fine suspended particles are removed from the aerated sewage. In the Multi-Flo this is accomplished using an array of fabric filter tubes. Suspended particles collect on the upstream side of the filter tubes and face back into the mixing (aeration) zone of the chamber. Clear effluent discharges from a weir which collects the filtered water.

 

Disinfection

Chlorine tablets stored in one or two tubes in a separate container, provide disinfection for units fitted with a chlorinator.

 

Basic Operation and Maintenance

START UP: Allow 6 to 8 weeks for sufficient bacteria to provide proper treatment in the mulit-flo system. During this period, there may be sudsing from laundry waste. Sudsing can be reduced two ways: By limiting the volume of laundry washed daily and by using low-sudsing detergent. Spread laundry washings out to prevent short term overloads in the multi-flo system.

PUMPING EXCESS SOLIDS*: Periodic pumping is necessary to remove excess bacteria and other solids. PUMPING FREQUENCY*: The rate of solids accumulation- and resultant pumping- is dependent upon the quantity and strength of waste water entering the system. Normally, residential system should be pumped every 2-4 years.

FILTER CLEANING*: Filter socks should be cleaned whenever a Mulit-Flo unit is pumped. Filters may need to be laundered if the aerator is shut off for extended periods or they are plugged by grease, soap, residue or solids.

CLEANING FREQUENCY*: Under ordinary conditions, the top of the hanger and weir should be cleaned during each routine inspection (every 6 months). Sludge should be removed from the interior of the filters whenever it exceeds 6 inches in depth or if clumps of floc float at the top of the filter.

AERATOR REPLACEMENT: Average life expectancy of the aerator is 3-4 years. Never operate the aerator when the tank is empty.

ALARM: Multi-Flo alarm systems indicate both aerator failure and filtering plugging.

*NOTE: Due to differences in wastewater strength, increased user abuse, and hydraulic surges, additional treatment facility and/or increased maintenance may be required.

 

Care of your Unit

Your Multi-Flo is a 500 or 1000 gallon per day treatment plant. Read the manual for your Multi-Flo system. To receive a copy contact:
Waste Treatment Systems, Inc.
1336 Stanley Avenue
Franklin, Ohio 45005

 

Questions

(513) 946-7800

 

Download a printable version of this fact sheet here.

 

250 William Howard Taft Road
2nd Floor, Cincinnati, OH 45219
Phone 513.946.7800 Fax 513.946.7890
hamiltoncountyhealth.org