ShapeRectangle 2ShapeXXnote2clipboardclockcredit@2xGroupShapeShapeShapeGroup 2GroupHeart - FontAwesomeGroupinstagram@2x (1)magnifying47map-markerGroupphoneShapesocial-pinterest-outlineGroupribbon001-test-tubeShapeShapesocial-youtube-outline

Fact Sheet: Home Aeration Units – Oldham

Home  >  Resources  >  Fact Sheets  >  Fact Sheet: Home Aeration Units – Oldham
Resources
Overview
Fact Sheets
Overview
Fact Sheet: Animal Quarantine
Fact Sheet: Backflow & Backflow Devices
Fact Sheet: Bed Bugs
Fact Sheet: Bedbug Guidelines for Travelers and Public Accommodation Facility Guests
Fact Sheet: Blue-Green Algae/Cyanobacteria Harmful Algal Bloom (HABs) Physician Reference
Fact Sheet: Bureau for Children with Medical Handicaps
Fact Sheet: Church Festival Food Safety
Fact Sheet: Cleaning up After Flood & Sewer Backups
Fact Sheet: Cockroaches
Fact Sheet: Collector Line Tips
Fact Sheet: Commercial Waste Handling and Good House Keeping
Fact Sheet: Connecting to Sewers
Fact Sheet: Cottage Food Operation
Fact Sheet: Dangers of Extreme Cold
Fact Sheet: Daycare Control Measures for Prevention of Communicable Diseases
Fact Sheet: Emergency Pet Kit
Fact Sheet: Extreme Heat
Fact Sheet: Farm Markets
Fact Sheet: Farmers’ Markets
Fact Sheet: Fight the Bite – Facts About Zika Virus
Fact Sheet: Financial Aid for Sewer Connections and Septic System Replacement
Fact Sheet: Fish Fry Food Safety
Fact Sheet: Flood Safety
Fact Sheet: Flooding in a Food Service Operation
Fact Sheet: Food Safety During Power Outages
Fact Sheet: Food Safety When Eating Out
Fact Sheet: Frozen Pipes
Fact Sheet: Gastroenteritis and Norovirus
Fact Sheet: Gastroenteritis in a Retirement/Assisted Living Facility
Fact Sheet: Get Rid of Roaches
Fact Sheet: Guide to Mosquito Control & Mosquito-borne Illnesses
Fact Sheet: Guidelines For Environmental Cleaning and Disinfection of Norovirus
Fact Sheet: Guidelines for Handling Bed Bugs in a School
Fact Sheet: Guidelines for Social Workers, Home Health Care Nurses, and In Home Visitors
Fact Sheet: Guidelines for the Control of a Suspected or Confirmed Outbreak of Viral Gastroenteritis in a Nursing Home
Fact Sheet: Hamilton County Public Health Flood Fact Sheet
Fact Sheet: Hand Washing
Fact Sheet: Handling Water from Swimming Pools and Hot Tubs
Fact Sheet: Heat
Fact Sheet: Hepatitis A
Fact Sheet: Home Aeration Units – Cavitette
Fact Sheet: Home Aeration Units – Coate Aer
Fact Sheet: Home Aeration Units – JET
Fact Sheet: Home Aeration Units – Multi-Flo
Fact Sheet: Home Aeration Units – Oldham
Fact Sheet: Home Swimming Pools
Fact Sheet: Homeowner’s Plumbing Permit
Fact Sheet: Household Sewage Treatment System Tips
Fact Sheet: Household Sewage Treatment Systems & Power Outages
Fact Sheet: How Germs Spread
Fact Sheet: How to be Safe Around Animals
Fact Sheet: Itch Mites
Fact Sheet: Keeping Food Safe During an Emergency
Fact Sheet: Leachfields
Fact Sheet: Lead Poisoning
Fact Sheet: Lice
Fact Sheet: Methicillin-Resistant Staphylococcus Sureus (MRSA)
Fact Sheet: Mold and Mildew
Fact Sheet: MRSA in a Prison Setting
Fact Sheet: Norovirus in Schools
Fact Sheet: Ohio EPA Semi-Public Sewage Disposal System Inspection Program
Fact Sheet: Privacy Practices, Our Legal Duty
Fact Sheet: Private Water System Testing
Fact Sheet: Rabies & Bats
Fact Sheet: Rodent Control
Fact Sheet: Scrap Tires
Fact Sheet: Septic System Abandonment and Sanitary Sewer Connection
Fact Sheet: Septic Systems – AdvanTex AX20 Treatment System
Fact Sheet: Septic Systems – Septic Tanks
Fact Sheet: Septic Systems – Subsurface Sandfilters
Fact Sheet: Sewage Treatment System Owners
Fact Sheet: Sewer Back-ups
Fact Sheet: Storm Drain Overflow
Fact Sheet: Stormwater Pollution and Yard Waste
Fact Sheet: Sump Pumps
Fact Sheet: Tattoos and Piercings
Fact Sheet: Vacuum Sealing + Hazard Analysis Critical Control Point (HACCP)
Fact Sheet: Waste Disposal
Fact Sheet: Water Heater Permits and Inspections
Fact Sheet: Well Disinfection
Fact Sheet: When Do I Need a Plumbing Permit?
Fact Sheet: Whooping Cough
FOI Requests
Links
Partner & Public Health Research
Reports

KNOW THE FACTS!

Home Aeration Units – Oldham

Illustration of your Unit

You currently live in an unsewered area of Hamilton County. The waste from your house is treated by a home aeration unit. These units come in many shapes and sizes. They are sometimes referred to as “cavitettes.” Cavitette is the brand name of one aeration unit used in our county. The other brands used are: Coate Aer, Jet, Multi-Flo, Norweco, and Oldham. Although aeration units have different brand names, the principle of operation is basically the same; air injected into sewage provides agitation and oxygen which allows bacteria to reduce organic waste to carbon dioxide and water.

 

Treatment Process

A properly operating home aeration unit will produce a clear, sanitary effluent. The following process is used.


Primary

(Pre-Treatment/Settling) Raw sewage from your home flows first to this chamber or trash tank (See #1). Here heavy matter sinks to the bottom; fats and oily matter float. Partially treated organic matter is suspended in the middle liquid portion.

 

Secondary (Aeration)

In the center chamber (#2), injected air provides agitation and oxygen to aerobic bacteria which further reduces organic matter in the wastewater.

 

Clarification

The third chamber (#3) has no agitation so suspended solids remaining in the aerated sewage can settle. This chamber is angled so solids return to the aeration chamber for further treatment.

 

Tertiary (Filtration/Disinfection)

The upflow filter is a separate tank (#4). Here clarified sewage is directed to the tank bottom via a PVC pipe. From there it flows upward through filter gravel, leaving the tank via a discharge weir. Chlorine tablets stored in a tube mounted on the inlet line or in a separate container provide further disinfection.

 

 

Care of your Unit

Your Oldham may be a 500 (4 lids) or 1000 (5 lids) gallon per day treatment plant. Read the manual for your Oldham system. To receive a copy contact: Robert R. Oldham Inc., P.O. Box 4406, Sidney, Ohio 45365.

Note: Some aeration units are installed deep below the surface of the ground. Maintenance to these units poses special safety problems and should be performed by a registered contractor. If you meet the preceding criteria or are uncomfortable with the following procedures, contact a maintenance company registered and bonded with the Health District.

Lids – All lids must be accessible and extend 4-6 inches above grade. Check lids for cracks that allow surface water to enter the system, or prevent Health District personnel from performing inspections. Lids that cannot be moved without cracking or falling apart must be replaced.

Trash Tank – Remove lid from the trash tank riser. Lift internal lid and probe the scum layer with a stick or pole. If layer is hard and/or more than 6 inches thick, the compartment should be pumped. Replace lids.

Aeration Tank – Remove lid from the aeration riser and check the following:

  • Electrical service wire-Replace if wire is frayed or black residue is present.
  • Air supply line-Line should be securely connected to the motor/blower and the diffuser bar.
  • Air bubbles-Turbulence and air bubbles in the wastewater indicates aeration is taking place.
  • Timer-Set timer to run 10-15 minutes every 30 minute cycle. (Make sure main power switch is “on”).
  • Motor/Blower-If the motor/blower is not running, touch carefully checking for warmth. The motor should be replaced/repaired if cold.
  • Replace lids.

Clarifier – Remove lid from the clarifier riser. Liquid should be clear, not cloudy or grey. If there is an accumulation of floating material, it should be skimmed and discarded. Replace lid.

Upflow Filter – Remove lid from the upflow filter. The filter should be cleaned if floating or suspended solids are present or if effluent is overflowing the concrete trough or PVC pipe. All aeration units should have a chlorinator. To avoid injury when replacing chlorine tablets, follow manufacturer’s directions. Replace lid.

Discharge Point – Check the discharge point. If discharge effluent is not clear, or black/grey matter is deposited at the discharge point, call a service contractor. Aeration unit discharge points are not appropriate play areas for children even when systems are operating properly.

 

Managing your Unit

Sewage tank pumpers must be registered with the Health District. The principle purpose of tank pumping is to remove sludge. You may want to be present at the time of pumping to insure all sludge and wastewater is removed. Contracted repairs must be performed by registered professionals. To receive a list of registered pumpers and contractors call the Health District at 513/946-7862.

 

Questions

For more information, contact the Water Quality Division at 513-946-7862 or visit www.hamiltoncountyhealth.org.

 

Download a printable version of this fact sheet here.

 

250 William Howard Taft Road
2nd Floor, Cincinnati, OH 45219
Phone 513.946.7800 Fax 513.946.7890
hamiltoncountyhealth.org